Shrink Packaging Troubleshootng Guide

Manual L-Bar Sealer

Is there power to the sealer ? CHECK Check to see that there is power to the sealer NO Turn on power to sealer
YES        
Is the sealing system heating ? CHECK Check to see if the heating system is heating NO Check heating control system, Seal wires, Heating elements
YES        
Are the sealing pads and tapes in good condition ? CHECK Check to see if the seal pads and or sealing tapes are in good condition NO Replace Seal pads and tapes as needed
YES        
Is the sealing wire coming into contact with the seal pad and or tape ? CHECK Check to see if the seal wire is hitting the seal pad and or tape NO Adjust the seal arm or seal pad so that they are in alinement
YES        
Is the sealing system at the proper temperature ? CHECK Check to see that the film is being cut off and sealed NO Adjust the sealing system temperature to proper level
YES        
Is the seal wire clean and strait ? NO Check the condition of the seal wire NO Replace the seal wire if not in good condition
YES        
Is the sealing wire that is being used the proper seal wire for the sealing machine ? CHECK Check to see that the proper seal wire is being used NO Replace seal wire with the proper seal wire
YES        
Is the film the proper film for the sealer being used CHECK Check to see if the film is the proper type and is not to old NO Replace with proper type film and newer stock
YES        