Description
The standard model L is a self-contained vacuum forming machine which does not require compressed air. This machine is a wonderful tool for sampling blisters, trays, skin packs, pre-production samples of all types and limited laboratory work. With the addition of some of the available options, the model L can be used for short run production of thermoformed parts.
Operation
The standard machine features hand controls for the up-moving forming platen, vacuum on and heater movement, while the automatic unit provides timer control of the heating time platen-up, and vacuum on sequences. Material is placed in the clamp frame, which is then closed, the heater is then pulled out over the material, and manual or automatic control of the forming functions is accomplished, the heater is pushed back to the insulated staging area, the stop button is then depressed to complete the forming cycle, the clamp frame is opened and the finished part may then be removed, and the process repeated.
Specifications
| Forming Area |
14" x 15" max. (Others available) |
| Cycle Speed |
variable, depends on application |
| Depth of Draw |
4" max. (Others available) |
| Air Requirements |
N/A on std. unit |
| Vacuum System |
positive displacement pump |
| Electrical |
110 Volts, 30 Amps |
| Heater System |
cal-rod |
| Weight |
200 lbs., approx. |
| Heat Time |
manual or adjustable 1 - 30 sec. timer |
| Weight |
600-1500 lbs. |
| Size |
26"W x 40"L x 26"H, approx. |
Options
- Special flat black type heater (220 V), replaces standard Cal-rod heater, typically used for production or specialty applications.
- Air operated forming platen, replaces standard self-contained platen movement system, allows better control of platen speed & repeatability, includes manual blow-off and air filter, regulator & gauge (requires customer shop air).
- Digital timer upgrade to automatic timer control machines, replaces standard rotary timer to provide better control and repeatability.
- Floor stand with casters and base for tool storage, allows Model L to be placed on stand.
- 220 Volt or 440 V system, rather than standard 110 V.
- Epoxy Paint: "Steel-It" or White; replaces standard tan enamel for medical, lab or special needs.
-
Tooling
- Form tools (CNC aluminum or other), water cooled tool mounting base, etc.
- Lab kit, consists of clamp frame adapter bars and platen stops to allow for use of alternate smaller sheet sizes.
|